Landmark, Manchester

Award-winning Landmark is located on St Peter’s Square, Manchester’s premier business district, and provides 180,000 sq ft of exceptional workspace, developed by Barings and designed by world-renowned architects Squire & Partners.

Eltherington carried out a full project specific CWCT test for the raisncreen facade on this award winning project.


The façade test rig, built for FK Group, passed the full CWCT Sequence B test. The test rig included large 3mm thick aluminium panels at 4m x 1m on our Hilti Eurofox subframe. CWCT sequence B tests the Air-Permeability, watertightness, wind resistance, water penetration and impact resistance.

Eltherington , 1305 Hedon Road, Hull, East Yorkshire HU9 5QD, UK 01482 320 336